Is There An Elegant Way To Extract Only The Properly-Paired Reads In A...
I know I should be filtering for the following tags: 99,163,83,147 and I know that samtools would work to get all the pairs. For example:samtools view -F 0x99 -b in.bam I was wondering if there was a...
View ArticleDoes Order Within Read Pairs In Interleaved Files Matter?
I have now ended up with interleaved paired-end read files where the order of reads is not the same throughout the file, ie. sometimes the forward read is first, sometimes the reverse read is first,...
View ArticleIs There Any Advantage Of Paired End Sequencing For Chip-Seq?
Hi,I hope that some of you may have a recommendation regarding the use of paired-end sequencing over single-end for ChIP-seq. In principle we expect only a minor improvement of using paired-end...
View ArticleDownload Large Paired-End Rna-Seq And Microarray Data Of The Same Sample (>...
Hi,I was trying to find if there is any large size paired-end RNA-Seq and microarray data of the same sample, but I wasn't able to find as much data as I wanted.Could somebody please point out where I...
View ArticleGsnap: How To Output Only Alignments With Minimal Number Of Mismatches?
I am aligning paired-end ChIP-Seq data of drosophila transcription factors.I would like to have a .sam file with the following alignments reported: - A maximum of three mismatches, i.e. three wrong...
View ArticleWhy Pair Ends Data'S Ecah Pair'S Alignment Statistic And The Sum Of Them Are...
I have a sample's data, using illumina 's Piar End sequencing technology.RE19E2T40PA_L1_I040.pairPrimer_1.fastq (Read1) RE19E2T40PA_L1_I040.pairPrimer_2.fastq (Read2) I have aligned both Read1 and...
View ArticleHow To Check If Illumina Fastq Is Single Or Paired End With Minimal Sequence Id
Hi all, I am trying to check if a FASTQ is single or paired end. From wikipedia I saw that default format has to be like this:@HWUSI-EAS100R:6:73:941:1973#0/1but in my case the sequence id is...
View ArticleCoverage For Pair-End Rna-Seq, Extend Reads Or Not?
HI, all I have a question when computing region coverage of pair-end RNASeq data. As showed by the sketch map, when computing region coverage, whether I should use actually mapped reads or extended...
View ArticleAligning Paired-End Reads In Single-End Mode
Hello,I have a question on how to align paired-end reads.In cases of very large fastq files, which make aligners like TopHat crash in a server with limited memory in RAM, I have seen people align one...
View ArticleJoining Paired-End Illumina Raw Reads
I recently have amplicons sequenced (Illumina PE250) to investigate microbial community. I want to know what quality detection, and what kind of trims of raw reads by what programs should be performed...
View ArticleNeed help using Shrimp2 on paired end color-space SOLiD data.
Hi, I have SOLiD reads which are paried-end (75bp and 35bp) in .csfasta and .QV.qual format. I would like to use Shrimp2 to align them. So far I have been having trouble using it. I used the following...
View ArticleSamtools Count Paired-End Reads
Hi, I used tophat to align paired-end reads from an rna-seq experiment and I obtained an accepted_hits.bam alignment file. Using the accepted_hits.bam I'd like to count the number of properly aligned...
View ArticleIn Paired-End Data, If One Read Of The Pair Is Unmapped, Is That Pair...
Hello everyone, I have a simple question about generic paired-end Illumina data. If one read of a pair is unmapped, does this automatically mean that the pair is improper and is (un)flagged in a SAM...
View ArticleDna Sequencing Using Abyss-Pe Of Paired End Reads
Hello! I've got to run abyss-pe on 2 files I've got and find the best parameters (k and so on) that would create the best contig coverage (sorry if I'm messing things up, I'm a programmer that had a...
View ArticleUnderstanding Samtools Flagstat Output
The following is the output of samtools flagstat command on bam file (paired-end) generated after markDuplicate of Picards.7417232 + 0 in total (QC-passed reads + QC-failed reads) 287618 + 0 duplicates...
View ArticleAligning Reads To Specific Chromosome Using Bwa
Hello Everyone,I have whole genome illumina paired end reads and I want to align my reads to specific chromosome (chr 21) using BWA. I was thinking of aligning the entire reads to fasta file of the...
View ArticleBwa Sampe Segmentation Fault
Hi everyone, I'm running bwa in the sampe mode and, after successfully processing >10M reads it fails with a segmentation fault (as follows) on what appears like a set of poorly-alignable reads. Any...
View ArticleHow To Interpret Crossbow Data
Hello,May I know how to interpret Crossbow output. Is there any chance of building a SAM or BAM file from Crossbow output. I am looking into genome mapping. I know there are many tools available for...
View ArticleBasic Paired-End Sam Questions
I can't seem to find answers to 2 very basic questions.For a paired-end sam, is there a separate sam line for mate1's and mate2's? If so, how do find the mate of a given sam line?Thanks
View ArticleDifference Between "Mate Pair" And "Pair-End"
Just as the title , I can't tell the difference between those two conception. :) waiting for your help.
View Article